Dometic RM 123E Refrigerator User Manual


 
5
Fig. 5
Fig. 6
Fig. 7
Leave as much space as possible
between the side of the ventilator
and the flue outlet.
Outer Cover of Flue Venting Kit.
DIMENSIONS OF RECESS
(with fr
ont ventilation)
Height of recess- 662 mm (26 1/16")
Width of recess - 383 mm (15 1/16")
Depth of recess - 400 mm (15 3/4")
(minimum).
VENT HOLE 40 mm (1 5/8") Dia. to
outside air, through floor or wall on
opposite side to burner.
FIG. 5a
UPPER
VENTILATOR
Wooden blocks for
securing upper
ventilator.
Vent hole in floor (see fig. 5a).
Where recess is above floor height,
the vent should be extended through a
pipe to the outside.
Ventilator
Work surface
100 mm (4")
minimum
Soft selaing
compound
Non-combustible
material
76 mm
(3")
662 mm
(26
1
/
16
")
400 mm
(15
3
/
4
") min
76 mm
(3")
76 mm
(3")