Electrolux 316488521 Ventilation Hood User Manual


 
88
88
8
Examples of possible ductingExamples of possible ducting
Examples of possible ductingExamples of possible ducting
Examples of possible ducting
Horizontal dischargeHorizontal discharge
Horizontal dischargeHorizontal discharge
Horizontal discharge
VV
VV
V
ertical dischargeertical discharge
ertical dischargeertical discharge
ertical discharge
RecirRecir
RecirRecir
Recir
culatingculating
culatingculating
culating
Installing the hood
Ductwork installation guidelines
For safety reasons, ducting should vent directly
outdoors (not into an attic, underneath the house,
into the garage or into any enclosed space).
Keep duct runs as short and straight as possible.
Duct fittings (elbows and transitions) reduce air flow
efficiency.
Back to back elbows and „S“ turns give very poor
delivery and are not recommended.
A short straight length of duct at the inlet of the
remote blower gives the best delivery.
Transition to duct from the integral blower or remote
duct transition as close to the downdraft as is pos-
sible.
In order of preference, use
1st. 10" round duct
2nd. 8" round duct
3rd. 3-1/4" x 14" duct
4th. 7" round duct
5th. 3-1/4" x l0" duct
6th. 6" round duct
The use of flexible metal round duct should only be
used when no other duct fitting exists. Limit use to
short lengths and do not crush when making
corners.
After having choosen the vent optionAfter having choosen the vent option
After having choosen the vent optionAfter having choosen the vent option
After having choosen the vent option, proceed as
follows:
Step 2Step 2
Step 2Step 2
Step 2
Remove the round transition from its seat by
unscrewing the its fixing screws (save the screws).
7" Round
Transition
Step 3Step 3
Step 3Step 3
Step 3
Remove the grease filters.