Electrolux 35772G Cooktop User Manual


 
11
Instruction for the Installer
Engineers technical data
BURNER RAPID SEMI-RAPID AUXILIARY TRIPLE
(large) (medium) (small) CROWN
POSITION MAX MIN MAX MIN MAX MIN MAX MIN
NOMINAL THERMAL
POWER (kW) 2.8 0.65 2.0 0.45 1.0 0.33 4.0 1.2
NOMINAL FLOW
RATE (m
3
/h) 0.266 0.062 0.190 0.043 0.095 0.028 0.381 0.114
NOZZLE REFERENCE 113 Adjust. 96 Adjust. 70 Adjust. 146 Adjust.
(1/100 mm)
NOMINAL THERMAL
POWER (kW) 2.8 0.65 2.0 0.45 1.0 0.33 4.0 1.2
NOMINAL FLOW
RATE (g/h) 202 47 144 32 72 24 288 86
NOZZLE REFERENCE 86 40 71 32 50 28 98 56
(1/100 mm)
NATURAL GAS
20 mbar
VALUE =
37.78 MJ/m
3
Ws - 50.7 MJ/ m
3
TYPE OF GAS
LPG GAS
28-30/37 mbar
VALUE =
49.92 MJ/Kg
Burner Dia. Tap By-pass
1/100 mm
Auxiliary 28
Semi-rapid 32
Rapid 40
Ultra-rapid 56
Aeration adjustment none
Supply Connections
Gas:R 1/2 inch (1/2 inch male) Rear right hand
corner
Electric: 230 V 50 Hz supply, 3 core flexible
cable with non rewireable plug fitted with a 3
amp cartridge fuse.
Heat Input
Ultra-rapid Burner 4.0 kW (13652 BTU/HR)
Rapid Burner 2.8 kW Natural Gas
(10239 BTU/HR)
2.8 kW L.P.G.
(9556 BTU/HR)
Overall dimensions
Width: 680 mm
Depth: 510 mm
Cut out dimensions
Width: 560 mm
Depth: 480 mm
Semi-rapid Burner 2.0 kW (6824 BTU/HR)
Auxiliary Burner 1.0 kW (3413 BTU/HR)
Appliance class 3
Appliance category II2H3+
Gas supply Natural gas G 20 / 20 mbar