13.2 Offeset pressure calibration
For the adjustment of the offset pressure, connect a manometer with a resolution of 1 Pa (100 Pa=1 mbar)
to the offset pressure test point after loosening the sealing screw. To adjust the cavity gas valve offset, set
a hot air cycle, half power; to adjust the boiler gas valve offset select a steam cycle, half power. Wait
around 3 minutes for the stabilization of the pressure before adjusting it turning slowly the screw indicated
in the picture above.