Electrolux E15IM60E Ice Maker User Manual


 
24
IMPORIMPOR
IMPORIMPOR
IMPOR
TT
TT
T
ANTANT
ANTANT
ANT
Ice thickness adjustment dial can be rotated 1/4 to 1/2 turn on the number dial. Allow the
ice maker to stabilize for 24 hours before making further adjustments. Since ice cubes
in any given batch will vary, choose cubes from the sample area for comparison when
making adjustments (see Figure 31). The factory setting is 0.
SAMPLE AREA
ICE005
Ice Cube Mold
Figure 30
Figure 31
Operation
3 Locate the ice cube thickness adjustment dial on the control board (see
Figure 30). Turn the dial clockwise (+ number) or counterclockwise
(- number) to thin the ice bridge.
4 Reinstall the front access cover.
5 Reconnect power to icemaker.
0
1
-1
2
-2
3
-3
4
-4
5
-5
ICE CUBE THICKNESS
ADJUSTMENT DIAL
DIAL IS
FACTORY
SET AT “0”