17
Installation
1 The range is equipped with a three-prong power cord (grounding plug which mates
with a standard three-prong grounding wall receptacle to minimize the possibility of
electrical shock hazard from the range).
2 Where a standard two-prong wall receptacle is encountered, it is the responsibility
and obligation of the customer to have it replaced with a properly grounded three-
prong wall receptacle. Do not cut or remove the grounding prong from the power
cord.
GROUNDING
CONNECT RANGE TO GAS SUPPLY
1 Turn off gas.
2 Install a male 1/2” flare union adapter to 1/2” NPT internal thread of regulator inlet.
3 Connect flexible gas line connector to end union and regulator inlet.
4 Install the male flare union adapter on the manual shut-off valve, taking care to support the
shut-off valve . Do not allow the valve to move or turn.
5 Position the range into the cabinet to allow connection of flexible connector at the shut-off
valve.
6 When all connections have been made, make sure all range controls are in the “OFF”
position and turn on main gas supply valve.
7 Use a leak detector at all joints and connections to check for leaks in the system. Do not
use a flame to check for gas leaks.
The appliance must be isolated from the building’s gas supply piping system by closing
it’s individual manual shut-off valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psig (3.5kPa).
NONO
NONO
NO
TETE
TETE
TE
The gas pressure regulator is preset at the factory for natural gas to use with the appliance. To
convert the range to LP gas, see instructions supplied in the LP conversion package.