Electrolux E36GF76GPS Range User Manual


 
19
WARNINGWARNING
WARNINGWARNING
WARNING
The range and shut-off valve must be disconnected from the gas supply piping during any
pressure testing exceeding 1/2 psi (3.5kPa).
The range must be isolated from the gas supply piping by closing the shut-off valve during
any pressure testing at or below 1/2 psi (3.5kPa).
NONO
NONO
NO
TESTES
TESTES
TES
If either the oven or cooktop does not operate properly follow these troubleshooting steps:
Verify the power and the gas are supplied to the range.
Check the electrical connections and gas supply to ensure the installation has been
completed correctly.
If the appliance still does not work, contact an authorized service company. Do not attempt
to repair the appliance yourself. Electrolux is not responsible for service required to correct
faulty installation.
Operation
VERIFYING THE OPERATION
Before beginning the test procedure, ensure that all cooktop control valves are in
the “OFF” position, and all burner rings, burner caps, and grates are properly
positioned on the top frame. Turn on the gas supply at the shut-off valve.
Turn on the power supply to the range. Select a temperature of 350°F by rotating
the oven selector knob to “350”. Rotate knob to the “Off” position to stop the
heating process.
Test each top burner separately by pressing and turning one control knob at a time
counterclockwise to the “HIGH” position. All ignitors will spark continuously, but
only the burner with gas flowing to it will ignite. (It will take approximately 4 seconds
for ignition to occur, at which time the ignitors will stop sparking. If ignition does not
occur within 4 seconds, turn off the knob, wait for at least 2 minutes to allow any
gas to dissipate, then repeat this ignition test.) The control knob can then be
rotated counterclockwise from “HIGH” to “LOW” to adjust the flame height
progressively.
Repeat the ignition test for all burners. When installed properly, the flame will be
steady and quiet. It will also have a sharp, blue inner cone that will vary in length
proportional to the burner size.