Electrolux EKM 70150 Cooktop User Manual


 
26 electrolux
This appliance must be installed in
accordance with the Gas Safety
(Installation and Use) Regulations (current
addition) and the I.E.E. Wiring
Regulations.
Detailed recommendations are contained
in the following British Standard Codes
of Practice - B.S. 6172, B.S. 5440: Part
2 and B.S. 6891: Current Editions.
For appliances installed in the Republic
of Ireland please refer to NSAI- Domestic
Gas Installation I.S. 813 Current Editions
and the ETCI Rules for Electrical
Installations.
Provision for Ventilation
The room containing the cooker should
have an air supply in accordance with
B.S.Codes Of Practice: B.S. 6172/ B.S.
5440, Part 2 and B.S. 6891 Current
Editions.
The following requirements for
ventilation must be met.
The cooker should not be installed in a
bed sitting room with a volume of less
than 20m
3
, if it is installed in a room of
volume less 5m
3
an air vent of effective
area of 100cm
2
is required; if it is
installed in a room of volume between
5m3 and 10m
3
, an air vent of effective
area 50cm
2
is required, while if the
volume exceeds 11m
3
no air vent is
required. However, if the room has a
door which opens directly to the outside,
no air vent is required even when the
volume is between 5m
3
and 11m
3
.
If there are other fuel burning appliances
in the same room, B.S. 5440: Part. 2:
Current Editions should be consulted to
determine the requisite air vent
requirements.
Important Safety Requirements
Location of the appliance
This cooker has been registered as a
"Class X" appliance according to Fire Risk
Regulations.
Any adjacent cabinets or walls must not
exceed the cooker's height.
The cooker may be located in a kitchen,
a kitchen/diner or bedsitting room but not
in a bathroom or shower room.
For information regarding the fitting of
flexible supply pipes, the highest
temperature at the rear of this cooker
which may come into contact with the
supply pipe is 70°C above ambient.
The minimum distance combustible
material can be fitted above the cooker
in line with the edges of the cooker is
420 mm. If it is fitted below 420 mm. a
space of 50 mm. must be allowed from
the edges of the cooker. However, it is
recommended that a clearance of
500mm is allowed.
The minimum distance combustible
material can be fitted directly above the
cooker is 650 mm.
L.P.G. cookers MUST NOT be installed
below ground level, i.e. in a basement,
or aboard any boat, yacht or other vessel.
Since the appliance is supplied with
adjustable feet, it should be located as
shown in the diagrams, according to the
height adjustment.
For appliances installed in the Republic
of Ireland please refer to NSAI- Domestic
Gas Installation I.S 813 Current Edition
Section 7- Permitted Locations of
Appliance.