Electrolux ENB 40405 S Freezer User Manual


 
32 electrolux
GB
stands level. This can be achieved by two
adjustable feet at the bottom in front.
Do not stand the appliance next to a
source of heat such as a radiator or
cooker.
Ventilation Requirements
The appliance must have adequate
ventilation to ensure correct operation.
Diagram shows the ventilation
requirements when installed:
A Under a cupboard.
B When freestanding
The climate classification can be found
on the rating plate.
The following table shows which ambient
temperature is correct for each climate
classification:
Climate Classification Ambient Temperature
SN +10 to +32 °C
N +16 to +32 °C
ST +18 to +38 °C
In the bag of the accessories there
are two spacers which must be fitted
in the two top corners.
Slacken the screws and insert the spacer
under the screw head, the re-tighten the
screws.
Levelling the Appliance
When placing the appliance ensure that it
Removal of glass shelf blockers
from the product
The glass shelf blockers are used to fix
the shelves into position during product
transport. These blockers will not be
necessary for the further operation of the
product.
Open the refrigerator door as wide as
possible.
1 Slide the blocker tabs to the front of the
shelf.