Electrolux EOG 621 Oven User Manual


 
15
FO 0374
Location of appliance
The appliance may be located in a kitchen, a kitchen/
diner or bedsitting room but not in a bathroom, shower
room or bedroom.
It is essential that there is a minimum clearance of 3mm
between the top surface of the appliance and the inside
top of the cabinet. The unit must be fitted into a cabinet
conforming to Fig.2.
This oven unit may be used in a Built-in or a Built-under
situation (see relevant diagrams). If the appliance is to
be built-under a hob, it is recommended thet the hob be
installed before the oven unit.
Building in
Please ensure that when the oven is installed it is
easily accessible for the engineer in the event of
a breakdown.
BUILDING IN
The surround or cabinet into which the oven will be built
must comply with these specifications:
l the dimensions must be as shown in the relevant
diagrams;
l the materials must withstand a temperature increase
of at least 60°C above the ambient temperature;
l proper arrangements must be made of a continuous
supply of air to the oven to prevent the oven overheating.
Dimensions of the oven and recess required are given
in the relevant diagrams (in millimetres).
FO 0290
580
560-570
550
4
4
0
m
in
110
min 550
110
591
min. 4
560÷570
min 550
140 240
591
min. 4
560÷570
110
FO 2129
FO 2128
Fig.1
Fig.2
Fig.3
Fig.4