18
ELECTRICAL CONNECTIONS
Any electrical work required to install this
hob should be carried out by a qualified
electrician or competent person, in accordance
with the current regulations.
THIS COOKER MUST BE
EARTHED.
The manufacturer declines any liability
should these safety measures not be
observed.
This cooker is designed to be connected to a
230-240V 50Hz AC electrical supply.
Before switching on, make sure the electricity
supply voltage is the same as that indicated on
the hob rating plate. The rating plate is located
on the bottom of the
hob.
The cooker is supplied without a supply cord. A
3 core flexible supply cord must be fitted, in
accordance with the specification given in the
relevant tables.
1. Loosen the two fixing screws securing
the back protective screen of the
cooker, then lift it up and remove it. This
will expose the terminal block on the
right bottom corner.
2. Loosen the two cable clamp screws and
lift the top section of the clamp enough
to allow the cable to be passed through.
3. Connect the red (live) wire to the
terminal which is marked with the letter
"L".
4. Connect the black (neutral) wire to the
terminal which is marked with the letter
"N".
5. After fitting a green or yellow/green
sleeve over the bare copper wire (earth
wire), connect the exposed end to the
terminal which is marked with the earth
symbol
or with the letter "E" coloured
green and yellow.
NOTE:
The earth wire should be about 2 cm. longer
than the live and neutral wires.
6. Secure the cable by means of the
clamp screws and refit the back
protective screen.
The cooker should be connected to a double
pole switch with a minimum gap of 3 mm.
between the switch contacts and of a type
suitable for the required load in compliance with
the current electric regulations. The switch
should be sited within 2m of the hob and be
easily accessible upon completion of the
installation.
The switch must not break the yellow and green
earth cable at any point.
Ensure that the hob supply cord does
not come into contact with surfaces
with temperatures higher than 50 deg.
C.
Supply Cable Specifications
For UK use only
Connection
Via
Min. size
Cable
Flex type Fuse
Cooker
Control
Circuit
6 mm²
Twin &
Earth
H05 VV-F 30 A
Please insert picture of the wiring
connection.
3x4 mm² or 3x6 mm²
230...240VAC
1
2
3
4
5
6
N
L