22
· there is good air circulation around
the cabinet and that the air channels
below and behind the cabinet are not
blocked. The ventilation sp ace above
the cabinet mu st be at least 4 cm.
The ventilation space can either be
a) directly above the cabinet, or
b) behind and above the t op cupboard.
In this case, the space behind the
cupboard must be at least 50 mm deep.
50mm
a)
b)
Cabinet is placed at a location where
the ambient temperature corresponds
to the climate classification*, for which
the appliance is designed.
* See on the r ating p late on the inside
of the appliance.
The following table shows which
ambient temperature is correct for
each climate classification.
Climate
classifi-
cation
for an ambient
temperature of
+10°C to +32°C
+16°C to +32°C
+18°C to +38°C
+18°C to +43°C
SN
N
ST
T
If the cabinet is placed in a corner and
the side with the hinges facing the
wall, the distance between the wall
and the cabinet must be at least 15
mm to allow the door to open enough
so that the baskets can be removed.
The power plug must be accessible
after installation of the cabinet.
Door Reversal
If necessary for your installation, the
door hinge may only be adapted by
an authorised plumbing technician. If
you need to re-hang the door,
contact your local Electrolux service
centre.
Important
!
Electrical conn ection
This appliance must be earthed.
If the plug that is fitted t o your
appliance is not suitable for your
socket outlett, it must be cut of and
the appropriate plug fitted.
Removethefusefromthecutoff
plug.The cut off plug should then be
disposed of to prevent the hazard of
socket inanother part of your home.
The wires in the mains lead are
coloured in accordance with the
following code:
Green and yellow -Earth
Blue -Neutral
Brown -Live
If you fit your own plug, the colours of
the Wires in the mains lead of your
appliance may not correspond with
the markings identifying the terminals
in your plug, proceed as follows: