Electrolux S92358-KA2 Refrigerator User Manual


 
22
AEG/Electrolux 8184261-00/9
Installation of carbon
filter
On delivery the carbon filter is
placed in a plastic bag to secure the
length of the carbon filter life. The
filter should be placed behind the
grill before the cabinet is turned on.
The cover can be opened by
simultaneously pressing the lever on
the right of the grill (1) and turning
the cover outward (2). The carbon
filter is then mounted in the slot
found in the back of the cover.
The filter should be handled
carefully so fragments do not loosen
from the surface.
1
Electrical cord
Do not remove the power cord by pulling on its lead, particulary when
the product is being pulled out of its niche.
· Damage to the cord may cause a short-circuit, fire and/or electric shock.
· In the event of damage to the appliance's main cable, only an authorised
service company recommended by the manufacturer or a similarly qualified
person may adjust it in order to avoid shock hazard for the user.
Installing the cabinet
Make sure that the power plug is not squashed or damaged by the back of
the product.
· A damaged power plug may overheat and cause a fire.
Do not place heavy articles or the product itself on the power cord.
· there is a risk of a short circuit and fire.
If the power plug socket is loose, do not insert the power plug.
· there is a risk of electric shock or fire.