Electrolux SG558 Cooktop User Manual


 
33
Technical details
Hotplate Natural Gas
R.H.F. R.H.R. L.H.R. L.H.F.
1.0kW 1.9kW 1.9kW 2.9kW
Heat input
(3412 Btu/h) (6483 Btu/h) (6483 Btu/h) (9895 Btu/h)
Injector marking 070 096 096 119
Hotplate L.P. Gas
R.H.F. R.H.R. L.H.R. L.H.F.
1.0kW 1.9kW 1.9kW 2.8kW
Heat input
(71.8g/h) (136.5g/h) (136.5g/h) (194.0g/h)
Injector marking 050 071 071 086
Grill
Heat Input 2.7kW (9215 Btu/h) 2.45kW (176.5g/h)
Injector marking 121 078
Second oven Natural Gas L.P. Gas
Heat Input 2.4kW (8189 Btu/h) 2.4kW (172.4 g/h)
Injector marking 108 078
Dual control
bypass
Fixed internal Fixed internal
Main oven Natural Gas L.P. Gas
Heat Input 2.4kW (8189 Btu/h) 2.4kW (172.4g/h)
Injector marking 108
078
Thermostat
bypass marking
069 078
General
Ignition (H.T. Spark)
Spark gap 3-4mm
Gas category Countries of destination
CAT. I2H GB
CAT. I3+ GB