Advanced Microprocessor with Graphics Control Setup
19
Figure 4 Advanced microprocessor with graphics (AG) control menu
Normal
Display
Date and Time
Set Clock
** Optional
Cursor Movement
Use UP/DOWN to move
the cursor. Hit ENTER to
select the menu item.
ESC key moves backward
through menus toward the
Main Menu.
Any Key
except
ON/OFF
ESC key
72°F Unit On
50% Reheat
Dehumidifying
Cooling
* * *Main Menu* * *
View Water
Detect Floor Plan
Setup Water
Detect Floor Plan
Use / to Locate File
Use ENTER to define file
High Temperature
Low Temperature
High Humidity
Low Humidity
Low Suction Comp 1
Low Suction Comp 2
Short Cycle Comp 1
Short Cycle Comp 2
Compressor 1 Overload
Compressor 2 Overload
Main Fan Overload
Loss of Power
Humidifier Problem
High Head Pressure 1
High Head Pressure 2
Change Filters
Loss of Air Flow
Custom Alarm 1
Custom Alarm 2
Custom Alarm 3
Custom Alarm 4
Setup Alarms
Active Alarms
Alarm History Log
View/Set
Alarms
Operating
Status
Date and
Time
Run
Diagnostics
Plot
Graphs
View/Set Control
Setpoints
Setup
System
Analog/Digital
Inputs
View Run
Hours Log
Operating Status
Compressor Cooling %
Heating %
Glycool %**
Chilled Water Valve %**
Humidification %
View/Set Control Setpoints
Temperature Setpoint
Sensitivity Setpoint
Humidity Setpoint
Sensitivity
High Temperature Alarm
Low Temperature Alarm
High Humidity Alarm
Low Humidity Alarm
Chilled Water**
Glycool**
Compressor 1
Compressor 2
Condenser
Reheat 1, 2, 3
Humidifier
Main Fan
View 24 Hour Run
Time History
Compressor 1
Compressor 2
Glycool**
Main Fan
Humidifier
Reheat 1, 2, 3
Chilled Water**
Heat Rejection
View Total Run Hours
Setup Analog Inputs
Analog Input 1 (2,3,4)
Slope
Units
Text
Intercept
Read Digital Inputs
Setup Digital Inputs
(How-to Text)
Analog Input 1
Analog Input 2
Analog Input 3
Analog Input 4
Read Analog Inputs
Analog Sensor #2 Plot
Temperature Plot
Humidity Plot
Analog Sensor #1 Plot
Analog Sensor #3 Plot
Analog Sensor #4 Plot
Modify Plot Scales
Modify Temp Scales
Modify Humidity Scales
Modify Analog Sensor
#1 Scale
#2 Scale
#3 Scale
#4 Scale
Test Control Board
Microcontroller
Show DIP Switches
Dipswitch 1
Dipswitch 2
Dipswitch 3
Dipswitch 4
Dipswitch 5
Dipswitch 6
Dipswitch 7
Test Outputs
Main Fan
Compressor 1
LLSV 1
HGBP/CUV 1
Compressor 2
LLSV 2
HGBP/CUV 2
CWV/CGV
RS Delay
Reheat 1
Reheat 2
RH3/Dehum Damper
HMV
Common Alarm
Air Sail Switch
Custom Alarm 1
Custom Alarm 2
Custom Alarm 3
Custom Alarm 4
Humidifier Problem
Filter Clog Switch
Main Fan Overload
High Head Compressor 2
Compressor 2 Overload
Shutdown Device
Low Pressure Switch 2
Low Pressure Switch 1
Compressor 1 Overload
High Head Compressor 1
Show Inputs
Calibrate Valve Actuator
Set Status Display
Sensor Reading
Setpoints
Select Humidity
Sensing Mode
Relative
Absolute
Select Control Algorithm
Proportional
Intelligent
Tunable PID
Proportional Gain
Derivative Gain
Integral Gain
Calibrate Sensors
Temperature Sensor
Humidity Sensor
Calibrated Reading
Change Passwwords
Setpoint Password
Setup Password
Change Passwords
Setup Operation
Cold Start Delay
Auto Restart Delay
IR Flush Overfill
CW/HW Coil Flush
Display in Degrees (F/C )
Min Chilled Water Temp**
Select Options
Reheat
Humidify
Dehumidify
Humidifier Pan Size
Hot Gas Reheat
Stages of Reheat
Dehumidification Stages
Setup Custom Alarms
Setup Custom Alarm Text
Change Custom Text 1
Change Custom Text 2
Change Custom Text 3
Change Custom Text 4