OPERATING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
A) This appliance is equipped with a pilot, which must be
lit by hand by following these instructions exactly.
B) BEFORE LIGHTING smell all around the appliance
area for gas, and next to the floor because some gas is
heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call the fire
department.
C) Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or
turn by hand, do not try to repair it . Call a qualified
service technician. Force or attempted repair may
result in a fire or explosion.
D) Do not use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of the
control system and any gas control which has been
under water
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above.
2. Turn off all electrical power to the
appliance.
15
HI \ LO knob Control knob
3. Turn the gas control knob clockwise
to the “off’ position.
4. Open door. Wait five (5) minutes to clear out any
gas. Close door. If you smell gas including near the
floor, STOP! Follow “B” in the above safety
information.
If you don’t smell gas go to next step.
5. Find the pilot located to the right between the front
and rear burner.
6. Turn gas control knob counter-
clockwise to “PILOT”.
7. Push the gas control knob in fully and hold.
Immediately light the pilot by pushing the piezo spark
igniter. Keep knob depressed for about 30 seconds
after pilot is lit. Release knob. If pilot goes out,
repeat steps 4 through 6.
WARNING The gas valve has a lockout device, which will
not allow the pilot burner to be re-lit until the
If the knob does not pop up when released, stop and
immediately call your service technician or gas supplier.
NOTE: Check to be sure the pilot flame engulfs the
thermocouple and that the burners light completely.
If the pilot will not
stay lit after several
tries, turn the gas
control knob to
“OFF” and call you
service technician
or gas supplier.
8. Turn gas control knob counter-clockwise
to the “ON” position.
Flip burner switch to “ON” then turn “HI / LO” knob to
the desired setting.
9. Turn on all electrical power to the unit
thermocouple, has cooled.
TO TURN OFF GAS TO APPLIANCE
1. Turn the gas control knob clockwise to “OFF” DO NOT FORCE
2. Turn off all electrical power to the appliance if service is to be performed.
3. Flip burner switch to off.