Everpure 80 Ice Maker User Manual


 
29 90846
YES
NO
2.D (CONT)
REPLACE PROBE WIRE ON
CONDUCTIVITY CONTROL
DURING HARVEST CYCLE.
DOES
TIMER RETURN
HOME?
WAIT ONE FULL FREEZING
CYCLE (APPROX. 6-10 MIN.)
DOES
HARVEST
INITIATE?
DOES
ICE HARVEST
NORMALLY?
DONE
YES
YES
YES
NO
NO
NO
1. REPEAT PREVIOUS CHECK OF OPERATION OF
HARVEST COMPONENTS IN 2.D
2. ADJUST ICE THICKNESS PROBE ONLY
AFTER ALL OTHER FACTORS HAVE BEEN CHECKED
THOROUGHLY.
1. CHECK PROBE WIRING FOR
SHORTED CONNECTION.
2. CHECK CONDUCTIVITY CONTROL.
1. CHECK ADJUSTMENT OF TIMER
CAM #1. (TIMER HOME)
2. CHECK TIMER SWITCH #1.
1. CHECK ADJUSTMENT OF TIMER
CAM #3. (HARVEST MOTOR)
2. CHECK TIMER SWITCH #3.
3. CHECK HARVEST MOTOR CAPACITOR.
4. CHECK HARVEST MOTOR.