Fisher & Paykel CG244 Cooktop User Manual


 
19
Installation instructions
3
Adjust the minimum burner setting:
When changing from one gas type to another, the
minimum valve output must also be correct,
considering that in this position the flame must be about
⁄” (4 mm) long and must remain lit even when the knob
is turned quickly from the maximum to the minimum
position.
The adjustment is performed with the burner lit, as
follows:
Turn the knob to the minimum position.
Remove the knob.
Turn the adjustment screw to the correct setting
with a screwdriver (Fig.17).
For LP/Propane gas, tighten the adjustment screw completely.
4
Re-test for leaks:
Repeat the steps under ‘Leak-testing the cooktop’.
5
Fill in/affix the gas conversion labels:
After completing the gas conversion, fill in the gas conversion labels (supplied with the
conversion kit).
Affix the adhesive/polyester label near the model/serial rating plate on the underside of
the basepan.
Affix the paper label into the appropriate frame at the front of this manual, under the
duplicate data (model/serial/rating) plate.
Gas rate summary
Fig. 17 Adjusting the minimum burner setting
CG122 models
Nominal
power
Reduced
power
LP/PROPANE
11” W.C.P.
NATURAL GAS
4” W.C.P.
Burners BTU/hr BTU/hr
injector
[1/100 mm]
By-pass
[1/100 mm]
injector
[1/100 mm]
By-pass
[1/100 mm]
Semi-rapid 6000 1500 72 34 118 adjustable
Rapid 10000 2000 94 44 155 adjustable
CG244 models
Nominal
power
Reduced
power
LP/PROPANE
11” W.C.P.
NATURAL GAS
4” W.C.P.
Burners BTU/hr BTU/hr
injector
[1/100 mm]
By-pass
[1/100 mm]
injector
[1/100 mm]
By-pass
[1/100 mm]
Auxiliary 3500 1000 55 27 90 adjustable
Semi-rapid 6000 1500 72 34 118 adjustable
Triple-ring wok 11500 5200 100 65 165 adjustable
Adjustment screw