Fisher & Paykel CG604 Cooktop User Manual


 
9
Installation instructions
Gas supply
The connection must be executed by an authorised person according to the relevant
standards.
Before connecting the appliance to the gas main, mount the brass conical adaptor onto the
gas inlet pipe, upon which the gasket has been placed (figures 5 and 6).
Conical adaptor and gasket are supplied with the appliance (packed with conversion kit for use
with Natural gas or Universal LPG).
This appliance is suitable for use with Natural Gas or Universal LPG. (Check the “gas type” sticker
attached to the appliance).
For Natural Gas models the gas supply is connected to the pressure regulator which is supplied
with the appliance (fig. 5). Adjust the regulator to obtain a test point pressure of 1 kPa with the
two semi-rapid burners operating at the maximum.
For Universal LPG models the gas supply is connected to the test point adaptor which is
supplied with the appliance (fig. 6) and ensure that the supply pressure is regulated to 2.75
kPa.
Do NOT force the ”elbow“ rotation prior to loosening nut.
Do NOT over tighten the nut at the ”elbow“.
Important!
This appliance IS NOT SUITABLE for installation with a hose assembly.
Gas connection for
UNIVERSAL LPG
Test point adaptor
Gasket
Brass conical adaptor
(Thread tight: use
suitable seal)
Gas inlet pipe
Test
point
Gas connection for
NATURAL GAS
Gasket
Brass conical adaptor
(Thread tight: use
suitable seal)
Gas regulator
Test
point
Fig. 5
Fig. 6