6
580
480
500
60
34
0
–2
560
200
0
–2
The installation shall comply with the dimensions in Figures 1 and 2, bearing in mind that:
A minimum clearance of 20 mm has to be kept between the bottom of the cooking hob and
the top of an appliance or a shelf. To ensure this clearance mount the spacers, supplied with
the appliance, as shown in the figure 3.
Overhead clearances - In no case shall the clearance between the highest part of the hob
and a range hood be less than 600 mm, or for an overhead exhaust fan, 750 mm. Any other
downward facing combustible surface less than 600 mm above the highest part of the hob
shall be protected for the full width and depth of the cooking surface area in accordance with
local regulations in force. However, in no case shall this clearance to any surface be less than
450 mm.
Side clearances - Where the dimension from the periphery of the nearest burner to any vertical
combustible surface is less than 200 mm, the surface shall be protected in accordance with
with local regulations in force to a height of not less than 150 mm above the hob for the full
dimension (width or depth) of the cooking surface area.
Where the dimensions from the periphery of the nearest burner to any vertical combustible
surface is less than 200 mm, the horizontal surface shall be greater than 10 mm below the
surface of the hob, or the horizontal surface requirement above.
Protection of combustible surfaces - Local regulations in force specify that where required
protection shall ensure that the surface temperature of the combustible surface does not
exceed 65 °C above ambient. The fixing of 5 mm thick ceramic tiles to the surface or attaching
fire resistant material to the surface and covering with sheet metal with minimum thickness of
0.4 mm should be satisfactory.
Fig. 1
0
– 2
0
– 2
Cooktop dimensions
Width 580 mm
Depth 500 mm
Depth below mounting surface 34 mm
Cut-out dimensions
Width 560 mm
Depth 480 mm
Installation instructions
This cooktop has been designed and constructed in accordance with the following codes and
specifications:
AGA101 (AS 4551) Approval Requirements for Domestic Gas cooking appliances
AS/NZS 60335-1 General Requirements for Domestic electrical appliances
AS/NSZ 60335-2-6 Particular Requirements for Domestic electrical cooking appliances
AS/NSZ 1044 Electromagnetic Compatibility Requirements.