The Product MUST NOT
be plugged in at this
stage.
WARNING
2.2.6
If required, trim the Single Connector to
the size which matches the waste tee or air
break to be used. There are ribs provided
to guide cutting.
When using the Single Connector, the hose
should be pushed in firmly, 5 clicks.
Remember to slip the Wire Clip over the
Drain Hose before connecting to the Single
Connector.
The supplied Wire Clip should be installed
between the two positioning ribs on the
Single Connector.
2.2.7
Attach Single Connector to waste tee.
Ensure snug fit using the supplied hose
clamp.
Ensure there is a power outlet in reach of
the supplied flex. If there is not a suitable
outlet available then have one installed by
a qualified electrician.
DO NOT modify the power plug supplied
with the DishDrawer or use an extension
cord, adaptor plug or multiple outlet box.
2.2.8
Alternatively, the DishDrawer may be
permanently connected to flexible conduit.
Remove the flex and cable clamp. Fit
suitable cable clamp for the conduit and
terminate the wiring as shown.
Use the solderless lug and washer supplied
with the product parts to terminate the
ground wire.
If permanently connecting,
ensure power is isolated.
WARNING
Page DS_08