Foster F60 Ice Maker User Manual


 
3
english
GB
how the installation
is made
location
Position the ice maker in its final location and
make sure that there is everything for its
installation, namely:
A minimum clearance of 15cm (6 in) must be
left at the sides of the machine for routing
cooling air drawn into and exhausted out of
the compartment to maintain a proper
condensing operation.
Fused switched power
supply.
19
20
Water supply
connection with
shut-off valve.
Waste drain water
connection.
21
22
Attention
Make sure that water
available is connected
to a cold drinking
water supply. If in
doubt consult the
installer for the possible
installation of a water
filter or water
conditioner.
To gain full advantage from this unit in terms of
performance and durability also make sure that:
Minimum water
temperature is not lower
than +5˚C and
maximum water
temperature does not
exceed +40˚C.
23
24
Minimum water
pressure is not below 1
bar and maximum
water pressure does
not exceed 5 bar.
The electrical suppy
available corresponds
to machine
specifications as
indicated on the unit
nameplate.
25
The electrical isolator switch
must be fitted with the correct
fuse rating.
26
27
The minimum ambient
temperature should not be
lower than +10˚C and the
maximum ambient
temperature higher than
+40˚C
There are no heat sources
(kitchen ovens, grills) near the
machine and the environment is
not too humid.
28
Important
The machine installation has to be performed by
Authorised Service Personnel
Connect the power lead to a
suitable electrical supply
29
30
Check machine is level.
The level can be
corrected by means
of the levelling feet.
31
32
Make the connection to
the water supply using the
hoses supplied with the
machine.
33
Water drain is connected
and set-up properly using
spiralled hose which
should have a minimum
fall of 3cm per metre.
start up
Open water shut-off
valve.
35
Switch the main switch to
the ON position.At this
stage the unit will start up.
37
36
Plug in machine.
34
It is recommended that
the interior of the
storage bin is cleaned
with an appropriate mild
disinfectant solution.
The Authorised Service
Agent will complete an
inspection of the unit
interior.
The first batch of ice cubes
will drop into the storage bin
approximately 30
minutes from start-up.
The first batch of ice will
be of poor quality but subsequent batches will be
good quality.
38
39
Attention
If the temperature of the
room in which the
machine is placed is
below +15˚C, the
freezing cycle length will
be shorter (17 to 20
minutes).
40
Alternatively, if the room
temperature is above
+30˚C, the freezing cycle
length will be longer (25
to 30 minutes).
14