13/ IF OPERATING ANOMALIES OCCUR
SUMMARY OF THE FAULTS
d01: water supply fault (tap) d07: overflow / anti-leak fault
d02: draining fault d08: sprinkling distribution fault
d03: heating fault d11: pressure sensor fault
d04: temperature fault d12: filling fault (water inlet detection system)
d05: fault – motor under load d13: overheating fault
d06: fault - motor overload
d14 : installation fault : (incorrect drainage
connection or inadequate flow rate and tap).
BEFORE CALLING FOR SERVICE
Problem Possible Causes What to do?
The door falls heavily when
opened (integratable model)
- Door springs not tensioned
enough to compensate for the
weight of the panel.
- Tighten the two tensioning
screws accessible in the bot-
tom section above the front
feet.
The door does not stay horizontal
when open or returns too
quickly
(integratable model)
- Door springs tensioned too
much.
- No wooden panel.
- Loosen the two tensioning
screws accessible in the bot-
tom section above the front
feet.
- Fit a temporary wooden panel
on the appliance and adjust
the springs.
The door catches when closing - Appliance not stable
- Door not centred on the tub
- Adjust the feet.
- Re-centre by adjusting the
rear feet.
The upper basket does not stay
in the high position
- Poor manipulation (the basket
is being pulled upwards too
quickly)
- Act more progressively (see
instructions), one side and
then the other.
Small leak around or under the
appliance (move the appliance
to locate the leak)
- Leak from the tap.
- Leak from the appliance.
(Cf. table fault d07).
- Check that a seal is fitted and
retighten the nut.
- Close the water tap and call a
technician.
Small leak at the door
- Appliance not stable or not level
- Door not centred on the tub.
- Adjust the feet.
- Re-centre by adjusting the rear
feet.
Tip:
If one of the above faults occurs and you need to call a repair man, remember to tell him