Frymaster 8196606 Fryer User Manual


 
Cabinet Troubleshooting
3-2
Failure modes not accompanied by a master control display are shown below with possible causes
and tests.
Symptom Possible Causes Tests
Unit fails to power
up; fans don’t run.
No power to cord.
Blown 20 amp fuse.
Circuit breaker open.
Check for line voltage at the switch
and the transformer.
Reset circuit breaker.
Unit powers up and
fans run; a display
fails to light.
Broken or improperly
seated ribbon cable.
Defective display.
Switch ribbon cable from functioning
display to failed component to isolate
problem.
Unit powers up and
fans run; all
displays fail to light.
Failed power supply.
Check for 5VDC at communication
board and distribution boards.
Rows heat
improperly or not at
all.
Improper wiring on
distribution board.
Defective distribution
board.
Defective heater.
Defective sensor.
Ensure heater leads and power inputs
on the distribution boards are properly
seated.
Test for 208VAC input on distribution
board and 208VAC output from heater
leads to heater plate when the unit is
calling for heat.
Switch power leads from properly
operating row to faulty row to isolate
problem.
Check resistance of RTD lead against
temperature chart. See Page 2-4.
Switch RTD lead from properly
operating row to faulty row to isolate
problem.
Test continuity of heater plate.