Cabinet Service Procedures
2-1
2 Service Procedures
DANGER: Failure to disconnect power from the unit before servicing could result in serious
injury or death. The cabinet power switch DOES NOT disconnect all incoming power to the
cabinet.
2.1 Updating Software/Capturing Configurations
The five sections of software on the cabinet can be updated individually. To ensure compatibility between cabinet
software and replacement boards, the software should be updated to the latest version at any board replacement. Follow
the directions below.
Software updates use the master control display to enter programming codes, scroll to areas to be revised, respond to
questions and exit. The control is annotated above. The arrow and OK buttons are illuminated when active.
Check Existing Versions
1. With the unit powered up, press the programming key.
2. Screen scrolls Enter Access Sequence.
3. Enter 090809 on keypad.
4. Press OK.
5. Scroll with arrow keys to view all software revision numbers:
Main
Boot Loader
Master Display
Distribution Board
Row Display
6. Press OK.
Fig.1:Thesides
areheldinplace
byscrewsnear
thebaseofthe
unitoneachside.
Fig.2:Tabsinthetopcapextendto
holesinthecabinet.Thetopissecured
withatthetabswithscrews.
Programming key:
Press prior to entering
programming code.
OK: Press to confirm
choices.
Arrows: Scroll to
choices.
Power Switch: Cycle
power between each
revision u
p
date.
Keypad: Enter
programming
d
NOTE: If the master control
displays an error message
during the install process, turn
the cabinet off for 30 seconds
and back on. Repeat install