Frymaster FMCFEC Fryer User Manual


 
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
1-34
1.10.2 Initial Troubleshooting, 24VAC Frying Systems (cont.)
PROBLEM PROBABLE CAUSE CORRECTIVE ACTION
A. Incoming gas supply pressures are
not within range [Natural- 6-14" W.C.
(1.49-3.49 kPa); Propane- 11-14"
W.C. (2.74-3.49 kPa)]
A. Inspect gas supply to fryer. Repair
and/or replace faulty components
(defective supply shut-off valves,
incorrect piping size, etc.)
B. Air in gas supply lines (new
installation).
B. Allow unit to cycle on and off for
approximately 30 minutes to force air
from gas manifold and lines.
Fluctuating or erratic
lighting of burner
flame.
C. Missing or poor target alignment. C. Replace missing target(s) and/or
ensure correct target alignment.
Thermostat will not
adjust to correct
temperature.
A. Thermostat is out of calibration. A. Calibrate thermostat. Replace
thermostat if calibration is not
possible.
1.11 Probe Resistance Chart
Probe Resistance Chart
For use with CF Series fryers manufactured with Minco Thermistor probes only.
F OHMS C F OHMS C F OHMS C F OHMS C F OHMS C
60 1059 16 130 1204 54 200 1350 93 270 1493 132 340 1634 171
65 1070 18 135 1216 57 205 1361 96 275 1503 135 345 1644 174
70 1080 21 140 1226 60 210 1371 99 280 1514 138 350 1654 177
75 1091 24 145 1237 63 215 1381 102 285 1524 141 355 1664 179
80 1101 27 150 1247 66 220 1391 104 290 1534 143 360 1674 182
85 1112 29 155 1258 68 225 1402 107 295 1544 146 365 1684 185
90 1122 32 160 1268 71 230 1412 110 300 1554 149 370 1694 188
95 1133 35 165 1278 74 235 1422 113 305 1564 152 375 1704 191
100 1143 38 170 1289 77 240 1432 116 310 1574 154 380 1714 193
105 1154 41 175 1299 79 245 1442 118 315 1584 157 385 1724 196
110 1164 43 180 1309 82 250 1453 121 320 1594 160 390 1734 199
115 1174 46 185 1320 85 255 1463 124 325 1604 163 395 1744 202
120 1185 49 190 1330 88 260 1473 127 330 1614 166 400 1754 204
125 1195 52 195 1340 91 265 1483 129 335 1624 168 405 1764 207