Frymaster H50 Fryer User Manual


 
1-6
4. On non-CE fryers only, place the gas valve in the ON position.
5. Place the fryer power switch in the ON position. When the burner has lit and burned steadily for
at least one minute, compare the gas pressure reading to the pressure for the corresponding gas in
the appropriate table below. The tables list the burner manifold gas pressures for each of the gas
types that can be used with this equipment.
Gas
Single
Vat
Dual
Vat
Natural Gas Lacq
(G20) under 20 mbar
77
Natural Gas Gronique *
(G25) under 25 mbar
10 10
Natural Gas Gronique
(G25) under 20 mbar
10 10
Butane/Propane
(G30) at 28/30 or 50 mbar
17 17
Propane
(G31) under 37 or 50 mbar
20 20
CE Standard
Burner Manifold Gas Pressures
Pressure (mbar)
* Belgian G25 = 7,0 mbar (single or dual)
Gas Pressure
Natural
3" W.C.
0.73 kPa
Propane
8.25" W.C.
2.5 kPa
Non-CE Standard
Burne r Manifold Ga s Pre ssures
6. To adjust the burner gas pressure, remove the cap from the gas valve regulator and adjust it to
the correct pressure.
Non-CE
Valve
CE
Valve
GAS VALVE REGULATOR CAP