Frymaster HLZ 22 Kitchen Grill User Manual


 
Frymaster L.L.C., 8700 Line Avenue 71106, P.O. Box 51000, Shreveport, Louisiana 71135-1000
318-865-1711 FAX 318-862-2394
Printed in the United States Service Hotline
Page
18
1-800-24-FRYER
Remove power from unit. On 208V units, disconnect black and white wires connecting
blower to heat and latching relays. The resistance between the wires should be between
55 and 65 ohms.
Remove power from unit. On 240V units, disconnect red and white wires connecting
blower to heat and latching relays. The resistance between the wires should be between
62 and 72 ohms.
10.10 Hi-limit
Symptom: No display on controller.
Test:
The hi-limit is in the 12-volt output from the transformer. Remove power from unit.
Disconnect the white braided lead from the wire leading from pin 1 on the computer plug.
Disconnect the white braided lead from the 12-volt side of the transformer. Check
continuity in the hi-limit circuit.
11 Wiring Diagram