Frymaster J2X Fryer User Manual


 
J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
CHAPTER 6: OPERATOR TROUBLESHOOTING
6-4
Pilot outage.
A. Automatic gas valve knob turned
to off position.
B. Low pilot flame.
C. Clogged pilot orifice.
D. Pilot burner clogged around pilot
generator.
E. Pilot flame blowing away from
pilot generator (excessive draft in
kitchen).
F. Pilot generator not inserted fully
into pilot burner.
G. Pilot generator low output.
H. High resistance in high-limit
thermostat contacts.
I. Defective pilot magnet in gas
valve.
J. Corroded connection where pilot
generator connects to gas valve.
A. Turn gas valve to PILOT position,
relight pilot.
B. Adjust pilot flame to 1 ½ inches
(38mm).
C. Remove and clean the pilot
orifice. Reinstall.
D. Remove pilot burner. Clean
burner.
E. Eliminate draft in the kitchen.
F. Reinsert pilot generator into pilot
burner until flame surrounds tip.
G. Replace pilot generator.
H. Replace high-limit thermostat.
I. Replace gas valve.
J. Clean pilot generator connection
at gas valve.