Frymaster 35 Fryer User Manual


 
2-8
5. Check the thermostat calibration or temperature programmed into the computer.
For units equipped with thermostat controls, refer to the Thermostat Calibration instructions
in Chapter 5.
For units equipped with other types of controllers, refer to the appropriate section of the
Frymaster Fryer Controllers User’s Manual,
provided with your equipment for instructions
on programming and operating your controller.
2.5 Converting to Another Gas Type
Your fryer is configured at the factory for either natural gas or Propane (LP) gas.
If you desire to switch from one type of gas to another, a gas conversion kit must be installed by a
Factory Authorized Service Center technician.
DANGER
This appliance was configured at the factory for a specific type of gas. Converting
from one type of gas to another requires the installation of specific gas-conversion
components.
DANGER
Switching to a different type of gas without installing the proper conversion kit may
result in fire or explosion! NEVER ATTACH THIS APPLIANCE TO A GAS SUPPLY
FOR WHICH IT IS NOT CONFIGURED!
Conversion of this appliance from one type of gas to another should only be
performed by qualified, licensed, and authorized installation or service personnel, as
defined in Section 1.7 of this manual.
CE Gas Conversion Instructions
1. Between G20- and G25-type Natural Gas, adjust the gas pressure at the regulator. (Refer to the
CE Standard Burner Manifold Gas Pressure Chart.) Do not change the orifice or pilot.
2. Between a 2
nd
family gas (G20 or G25) and a 3
rd
family gas (G31 Propane):
a. Change the orifices.
b. Change the pilot.
c. Change the gas valve regulator or the gas valve.
d. Adjust the manifold pressure.
3. Affix the new label included with the conversion kit next to the existing rating plate stating that
the gas type has been converted. Remove any references to the previously used gas from the
existing rating plate.
4. If the destination language changes, replace the labels. Call your local service agency or kitchen
equipment supplier for a label kit. The language of reference will be on the corner of the label.