Gaggenau AH 530-720 Ventilation Hood User Manual


 
The appliance must be disconnected from the
power supply during all repair work.
If the appliance does not function correctly, check
the fuses first.
If the power supply is functioning correctly, but your
appliance still does not work, please contact your
Gaggenau dealer who will provide you with the
address and telephone number of your nearest
manufacturer’s authorized service agent or contact
Gaggenau USA on (800) 828-9165. Specify the
appliance type (see rating plate).
Repairs may only be carried out by authorised
technicians, in order to guarantee the safety of the
appliance.
Unauthorised tampering with the appliance will
invalidate any warranty claims.
Only ever use original spare parts.
Lamp replacement
Caution: Disconnect the power supply before
replacing lamps (switch off the fuse)!
Caution: Lamps may still be hot shortly after use!
Risk of burns.
– Detach the ring from the lamp cover.
Note: Make sure that the glass will not fall out
(Fig. 16).
– Pull out the lamp (Fig. 17).
Defective lamps must only be replaced by lamps of
the same type! (12 V/20 W/G4 lampholder)
Inserting the lamp
– Insert the lamp in the lampholder.
Note: Do not touch the halogen lamps with your
hands. Use a cloth and touch the lamp only on its
edges.
– Engage the lamp cover.
– Connect the appliance to the mains again.
12
5. Maintenance
Fig. 16
Fig. 17