Gaggenau AH 600-190 Ventilation Hood User Manual


 
Flexible aluminium pipes, corrosion-protected
sheet metal pipes and exhaust air pipes whose
material conforms to fire B1 in accordance with
DIN 4102 can be used. Exhaust air pipes should
have a nominal diameter of 150 mm.
Pay particular attention to ensuring that
the exhaust air ducts and pipes are kept as short
as possible
the pipes are not laid at an acute angle, but as
bends and that they are inserted into the shaft at
an inclined upward angle and
there are no cross-sectional constrictions in the
upward direction (this reduces the volume flow).
As standard, the blow-out opening of the wall hood
is in the upward direction.
To pass exhaust air through the outer wall, we
recommend the use of our telescopic wall box
TM 150-045 (Ø 150).
Note:
To prevent the ingress of water, e.g. condensate or
rain water from an uncovered exhaust air shaft, our
condensate separator RV 060-150 must be installed
in the exhaust air line. The condensate separator
must still be acciessible after installation.
Air recirculation
You need the following accessories to install the
air recirculation hood:
KF 600-090: activated charcoal filter:
Depending on the ceiling height, the following duct
units are at your disposal for air recirculation:
LK 600-110: Ventilation duct for a ceiling height
of 2.39 - 2.60 m
LK 600-120: Ventilation duct for a ceiling height
of 2.61 - 3.00 m
The dimensions above refer to a distance of 1.60 m
from the floor to the bottom edge of the hood.
Exhaust air operation
Depending on the ceiling height, the following duct
units are at your disposal for exhaust air operation:
LK 600-010: Ventilation duct for a ceiling height
of 2.27 to 2.60 m
LK 600-020: Ventilation duct for a ceiling height
of 2.61 - 3.00 m
The dimensions above refer to a distance of 1.60 m
from the floor to the bottom edge of the hood.
If required, a side outlet for the air duct is available
at an extra charge.
The socket must be place behind the duct cover on
the wall.
13
520
260
150
480
1600
522.5
min. 600
over electric cooker
min. 670
over gas cooker
Exhaust air:
750 - 1400
Air recirculation:
825 - 1400
Hood height
Exhaust air: 2.35 - 3.0
Air recirculation: 2.43 - 3.0
Ceiling height
Sus-
pension
Fig. 17