Gaggenau Wok Cookware User Manual


 
12
Technical data (gas)
Burners: super strong burner
Level 1 low flame < 850 BTU (0.25 kW)
Level 2 full inner flame < 1700 BTU (0.50 kW)
Level 3 small outer flame
plus level 2 full inner flame3 500 BTU (1.50 kW)
Level 4 full flame 17 000 BTU (5.00 kW)
Gas connection:
R 1/2’’ union nut for R 1/2’’ bracket to DIN 1999,
conical-cylindrical
Technical data, gas
Technical data (electrical)
Rated consumption 0.8 W
Voltage AC 120 V
Frequency 60 Hz
Technical modifications reserved.
6. Technical data / Table
Countries US US
CA CA
Gas family Natural gas Propane gas
Gas type NX
Pressure 6” W.C. (1.5 kPa) 10” W.C. (2.5 kPa)
Outer burner, full 170 B 1.10
Outer burner Bypass 0.79 0.57
Inner burner, full Nr. 44 Nr. 3
Inner burner Bypass 0.44 0.31
Air gap adj / outer [mm] 2 0
Air gap adj / inner
1
/
2
open open
∑ Power 17 000 BTU (5 kW) 17 000 BTU (5 kW)
∑ Consumption 0.48 m
3
/h 364 g/h