Part # 4522970 Rev 1 (10/28/09)Page 4
DIMENSIONS AND SPECIFICATIONS
SHIPPING
INFORMATION
MODEL
Weight
Lbs/Kg
HEEE-24CL 338/153
HEEE-36CL 391/177
HEEE-48CL 505/229
HEEE-60CL 620/281
Garland/U.S. Range products are not approved or authorized for home or residential use,
but are intended for commercial applications only.
Garland / U.S. Range will not provide service, warranty, maintenance, or support of any
kind other than in commercial applications.
Many local codes exist and it is the responsibility of the owner and installer to comply
with those codes.
Model #
Dimensions: In. (mm)
No. Of
Burners
Total BTU* Gas Broiling Grid: In. (mm)
Width Depth Height Natural Propane Width Depth
HEEE-24CL 24(610) 37-1/4(946) 17-13/16(453) 4 54,000 50,000 20-1/8 (511) 23-1/2(597)
HEEE-36CL 34(864) 37-1/4(946) 17-13/16(453) 6 70,000 72,000 30-1/8(765) 23-1/2(597)
HEEE-48CL 48(1219) 37-1/4(946) 17-13/16(453) 9 105,000 105,000 44-1/8(1121) 23-1/2(597)
HEEE-60CL 58(1473) 37-1/4(946) 17-13/16(453) 11 115,000 138,000 54-1/8(1375) 23-1/2(597)
* Manifold operating pressure as per table shown below
Gas Manifold 3/4" NPT on all model
38.75"
[978mm]
35.30"
[897mm]
.91"
[23mm]
4.61"
[112mm]
A
B
C
37.25"
[946mm]
8.47"
[215mm]
14.58"
[370mm]
17.84"
[453mm]
1.50"
[38mm]
28.71"
[729mm]
38.75"
[984mm]
ELECTRIC CORD CONNECTION
Width Measurements In (mm)
Model A B C
HEEE-24CL 14.28 (363) 23.50 (597) 24.00 (610)
HEEE-36CL 24.38 (721) 33.50 (851) 34.00 (864)
HEEE-48CL 38.28 (972) 47.50 (1206) 48.00 (1219)
HEEE-60CL 48.28 (1226) 57.50 (1460) 58.00 (1473)
Models
Manifold Operating Pressure Minimum Supply Pressure
Natural Gas Propane Natural Gas Propane
"w.c(Mbar) "w.c.(Mbar) "w.c.(Mbar) "w.c.(Mbar)
All Models 4.0(10) 10.0(25) 5.0(12.5) 11(27.5)
Electrical : 120V, 60 Hz 15 Amp
Supplied with NEMA 5-15 P Power Cord
NOTE: Wiring Diagram is located in right side of broiler’s leg
section.