GE JBS03GP Range User Manual


 
STEP 2
PREWRE FOR ELECTRICAL CONNECTION
Use only a 3-conductor, or if required a 4-
conductor range cord set as noted below.
These cord sets are provided with ring
type terminals.
The electrical rating of the cord must be
125/250 volts minimum, 40 amperes.
NOTE: Only a 4-conductor cord is to be used
when the appliance is installed in a mobile
home or where local codes do not permit
grounding through the neutral.
STEP 3
1. Locate connector block at the bottom rear
of range and remove rear wiring cover.
2. Directly below the connector block is a
hole with a knockout ring for accommodating
conduit fittings. Brackets provided are used to
support the flexible cord strain relief, which
must be securely attached to the cord set.
WIRING COVER
J
CTOR
STEP 4
!?%.%
3+VIRE SYSTEM
.>
Power Cord Installation-Insert screws
through power cord terminals so that the
screws pass through connector block terminals
and engage nuts. Tighten screws securely.
SCREW +
POWER CORD
RING TERMINAL
&k
&L
&
+ POWER
CORD
:~@l:~CTOR /
e
MOVABLE
TERMINAL
NUT
I
Cable Direct Installation-Clamp bare wires
between the connector block terminals and
movable nuts with screws tightened securely.
“b
$?
+ SCREW
e
~ f2~#:~CTOR
BARE
TERMINAL
WIRE~
@w
FLEXIBLE
CABLE
MOVABLE
NUT ~
I
1. Copper Wiring
Connect the neutral or grounded wire of the
supply circuit to the neutral terminal of the
connector block, located in the center. The
power leads must be connected to the outside
(brass colored) terminals.
GROUNDING STRAP
(GROUNDED TO RANGE)
J’
26