GE JBS56 Range User Manual


 
37
Installation Instructions
POWER CORD AND STRAIN RELIEF
INSTALLATION
Remove the wire cover (on the lower back of
the range) by removing two (2) screws using a
1/4” nut driver.
Do not discard these screws.
Remove the knockout ring (1
3
8) located on
bracket directly below the terminal block. To
remove the knockout, use a pair of pliers to
bend the knockout ring away from the
bracket and twist until ring is removed.
B
A
3
For power cord installations only (see the
next step if using conduit), assemble the
strain relief in the hole. Insert the power cord
through the strain relief and tighten. Allow
enough slack to easily attach the cord
terminals to the terminal block. If tabs are
present at the end of the winged strain relief,
they can be removed for better fit.
NOTE: Do not install the power cord without
a strain relief. The strain relief bracket
should be installed before reinstalling the
rear range wiring cover.
Skip to Step 4 or 5.
C
Wire cover
2 screws to
remove wire
cover
Knockout ring
in bracket
Knockout ring
removed
Power cord
Strain relief
Terminal
block
Bracket
Retaining
tab
Back of range
Terminal block
(appearance
may vary)
For conduit installations only, purchase a
squeeze connector matching the diameter of
your conduit and assemble it in the hole. Insert
the conduit through the squeeze connector and
tighten. Allow enough slack to easily attach the
wires to the terminal block.
NOTE: Do not install the conduit without a
squeeze connector. The squeeze connector
should be installed before reinstalling the rear
range wiring cover.
Skip to Step 6 or 7.
D
Squeeze
connector
Terminal
block
Conduit
Bracket