GE PD900 Range User Manual


 
5
Installation Instructions
The Standard Installation of this Drop-In
Range is to hang by the countertop on the
sidemetalangesunderglasscooktop.
ThisRangemustnotbeinstalledona
baseorsubstructure(2x4 support).
If the construction of your cabinet cannot
providea1/4”atareaatthebackofthe
countertop opening, consider changing the
countertop to accommodate this dimension.
Iftheareaisnotat,excesstensionmay
beappliedtotheglasscooktop,causing
breakageandvoidingthewarranty.
Center the 30” wide opening over the ad-
jacentcabinetsandmarkwithastraight
edge.
Usingastraightedge,markthebacklineat
23-3/16” from the front edge of the counter.
Be careful not to damage the adjacent
cabinets while cutting the countertop.
Remove countertop raised edge, if
incorporated. (See illustration on page 4)
StandardInstallationPreparation
B
B1
B2
B3
B4
STANDARDINSTALLATION
Wall
1/4 Min.
Flat
23-3/16
9/16 Min.
Flat
9/16 Min.
Flat
29-15/16–30-1/16
SmoothCut
25 Typically
1/4
R
Flat
Area
Countertop
RangeSupport
Bracessecuredbetweenthe
underside of the countertop and
thecabinetifrequiredtoobtain
1-1/4minimumthickness(two
sides)