GE Monogram ZEM200WV Microwave Oven User Manual


 
ZEM200WV
In-wall
installation
(continued)
ZEM200WV
Under-cabinet
mounting
Installation Preparation
Microwave Oven
• When cabinet depth is a critical factor, receptacle
should be installed in a side wall at rear of opening:
14 -5/8" minimum cabinet depth is required.
Receptacle installed in side
wall.
Receptacle installed behind
oven, flush with wall.
• If receptacle is located behind oven, install receptacle
flush with wall to minimize depth:
16" minimum depth is required.
Receptacle installed behind
oven, extended into cabinet.
• If receptacle is located behind oven and extended
into cabinet:
18" minimum cabinet depth is required.
• A 3-prong grounded receptacle must be within reach
of the oven’s 57" power cord, but located out of view
when oven is installed.
• Allow access for plugging and unplugging; do not
place receptacle directly behind oven.
7