GE Monogram ZEW165 Cooktop User Manual


 
Gas and Electrical Supply
Component Cooking Surfaces
5
Gas
Step
supply
location
Tools and materials
required:
Pipe and fittings as required.
Manual gas-line shut-off
valve.
Monogram component gas cooktops (used with either
updraft or downdraft venting) are designed to operate
on natural gas at 4“ water column pressure. Cooktop is
supplied with 3/8” NPT female gas connection at right
rear corner for right hand control unit and left rear
corner for left hand control unit.
. Component gas cooktops cannot be converted to
liquid propane gas operation.
Make gas connection through rear wall, or on cabinet
floor at rear.
For rigid connection:
Locate pipe stub:
- 47/1 6“ from center line of cooking unit.
on back wall at least 12” below counter or
on floor 2-1/2” forward of back of counter cutout.
Refer to cutout information for details on
ge
Gas Supply Options
‘Important 12- min. is specified
to allow space for shut-off valve if
supply is opted to enter from rear.
.“ .
uiagram 4YI
countertop cutouts.
For flexible connection:
Both left and right-controlled gas units are illustrated
. Locate pipe stub on floor or back wall in a convenient
togetherinordertocomparetheir supply rough-in
location.
locations.
. Install a manual shut-off valve in gas line in an easily
accessible location.
6
Step
Electrical
Toolsand materials required:
supply
120and 240 volt junction boxes.
location
Electrical cable as required by local codes.
Monogram Halogen/Radiant, updraft grill and
downdraft grill component cooktops operate on
208/240 volt 60 Hz; the gas component cooktops and
downdraft vent component operate on 120 volt 60 Hz
from a separate junction box. A dedicated circuit,
protected by a time delay fuse or circuit breaker, is
required for cooktops; the downdraft vent requires an
appliance circuit with a time delay fuse or circuit breaker.
If local codes allow, more than one cooktop can be used
on the same branch circuit.
See local codes or the National Electrical Code for circuit
demand loads. The downdraft vent component features
an integral variable-speed blower control switch.
/--?-.
.-
<
~o.\ ,
/
40”radius ,
/
radius #
[
electrical
electrical
\
outlet area I -. ‘Utlet area
Z17!i$
IL
(p
4“
electrical
~ power
o
cord
zEvvi45T
location
/’
~’\
a’
e
P
c
locat’on ZEW155N
\
35” radius
electrical”,
-1-
Y-- i
-.,,
AR’;;::;;;l~i
outlet area
‘1” \r2”
I/out’etarea
electric
power
cord
location
ZEW165N
Dtagram 49Z
49