GE Monogram ZEW175 Cooktop User Manual


 
4
Step
Installing
theDuctwork
(continued)
II
Optional
duct
arrangement
under
concreteslab
Finalize
ductwork
Diagram 471
The illustration above is applicable only to downdraft
vented cooktop installation into slab construction.
Use recommended wall caps with damper. Laundry
type wall caps should never be used.
- Ductwork must be vented to the outside.
. 6“ PVC duct should be used when installing under
Note: Localbuilding code must
a concrete slab.
be followed for installation and
. Each cooktop blower system requires a separate duct
in specifying approved type and
system.
schedule of PVCduct
used.
Airflow
+5
r
Duct Tape
Over Seam
and Screw
L
Screw
Diagram 472
.
Install ductwork, making connections in direction of
airflow as shown.
. Secure alljoints in ductwork with sheet metal screws.
. Wrap joints with duct tape for airtight seal.
. Install a wall cap with damper or roof cap at exterior
opening.
47