SCHEMATIC DIAGRAM
4-3
RD
RD
BK
PRIMARY
SWITCH
WH
WH
WH
WH
YL
MAGNETRON
RD
H.V.
CAPACITOR
H.V. DIODE
FUSE
20A
AC 120V
60Hz
BL
L
N
MICOM
CONTROLLER
F.M.
TRANSFORMER
H.V.
** NOTE : DOOR IS OPENED.
BK : BLACK BL : BLUE YL : YELLOW RD : RED
WH : WHITE PK : PINK GN : GREEN BN : BROWN
T.T.M.
O.L.
CN1
PT1
1
2
3
4
5
6
7
8
BK
BK
GN
GN
PK
BN
SECONDARY
SWITCH
OVEN
LAMP
MONITOR
SWITCH
TURN
TABLE
MOTOR
FAN
MO TOR
IMPORTANT SAFETY NOTE: THE SHADED AREAS ON THIS SCHEMATIC DIAGRAM INCORPORATE SPECIAL FEATURES
IMPORTANT FOR PROTECTION FROM MICROWAVE RADIATION, FIRE, ELECTRICAL SHOCK, AND
HAZARDS. WHEN SERVICING IT IS ESSENTIAL THAT ONLY MANUFACTURER'S SPECIFIED PARTS
BE USED FOR THE CRITICAL COMPONENTS IN THE SHADED AREAS OF THE SCHEMATIC DIAGRAM.
NOTICE: SINCE THIS IS BASIC SCHEMATIC DIAGRAM, THE VALUES OF COMPONENTS AND
SOME PARTIAL CONNECTIONS ARE SUBJECT TO CHANGE FOR IMPROVEMENT.
RY1
RY2
GN
WH