Sanitizing Carburetor and Valve Components (cont.)
8. Slide the valve plunger spring over the small end of the valve
plunger and, using another clean piece of paper toweling, pick up the
valve plunger at the outlet end and insert plunger and spring into the
valve body (figure Q).
9. Push up on the valve plunger and insert the stainless steel handle
(figure R).
10. Insert the dispensing valve handle retaining pin (figure S)
Sanitizing and Refilling
1. Pour sanitizing solution into the mix storage hopper and allow the
solution to fill freezing cylinder. Use a large brush (supplied) to
sanitize all hopper surfaces (figure T).
2. Turn panel switch to “CLEAN” and allow freezer to run for 20
minutes.
3. Open dispensing valve and drain solution. Allow the auger to push
remaining sanitizer out of the freezing cylinder.
4. Place a small amount of sanitary lubricant onto another piece of
clean paper toweling (figure U).
5. Use a clean piece of paper toweling to pick up the large end of the
carburetor from the bottom of the hopper taking care not to touch the
sanitized carburetor with your bare hands.
6. Apply the lubricant on the other piece of paper toweling to the two “O”
Rings on the bottom of the carburetor assembly (figure U).
7. Place the lubricated carburetor assembly on a clean piece of paper
toweling.
8. Use either fresh product or mix new product according to
manufacturer’s instructions.
9. Fill mix storage hopper with product.
10. Open dispensing valve. Pour product into the hopper and allow this
product to chase out any remaining sanitizer.
Figure Q Installing Plunger and Spring
Figure S Insert Retaining Pin
Figure T Sanitize Hopper
Figure U Lubricate Carb Tube
Figure R Insert Valve Handle