Grindmaster APBIC-330V2 Coffeemaker User Manual


 
Shuttle Brewers & Airpot/Shuttle Brewers Page 7
Adjustments
All adjustments to machine are accessible through the front display(s). Refer to specifics below and the
Programming Routine section. All values are preset at the factory and may vary brewer to brewer.
Temperature Adjustment
Tank temperature can be adjusted from 170°F – 205°F (77°C – 96°C) through the front display. See Programming
Routine section for procedure.
Altitude (ft)
Approximate Boiling Point Recommended Max. Temperature
°F °C °F °C
0 212 100 205 96.1
500 211.1 99.5 204 95.6
1000 210.2 99.0 203 95.0
1500 209.3 98.5 202 94.4
2000 208.4 98.0 201 93.9
2500 207.5 97.5 200 93.3
3000 206.6 97.0 199 92.8
3500 205.7 96.5 199 92.8
4000 204.8 96.0 198 92.2
4500 203.9 95.5 197 91.7
5000 203 95.0 196 91.1
5500 202 94.4 195 90.6
6000 201.1 93.9 194 90.0
6500 200.2 93.4 193 89.4
7000 199.3 92.9 192 88.9
7500 198.3 92.4 191 88.3
This brewer can be set for maximum water temperature of 205°F (96°C). The boiling point of water is lower as
altitude increases. The setpoint temperature of the brewer should be maintained below the boiling point at a given
elevation. Refer the to the chart below for recommended maximum setpoint for given altitudes.
THERMISTOR CURVE FOR PART # A725-097
°C °F RESISTANCE (OHMS) °C °F RESISTANCE (OHMS)
0 32 16325 60 140 1244
5 41 12697 65 149 1041
10 50 9951 70 158 875
15 59 7856 75 167 740
20 68 6246 80 176 628
25 77 5000 85 185 535
30 86 4028 90 194 458
35 95 3266 95 203 393
40 104 2663 100 212 339
45 113 2185 105 221 294
50 122 1802 110 230 255
55 131 1493