Grindmaster TEA-300 Ice Tea Maker User Manual


 
Set-Up / Position
1. Position the brewer on a strong, stable counter top or table.
2. Check the level front to back and side to side. Adjust the legs to the correct level.
3. See rough-in drawing in this manual for dimensions and locations of electrical and water input.
Water Hook-Up
IMPORTANT
WATER PIPE CONNECTIONS AND FIXTURES DIRECTLY CONNECTED TO A POTABLE WATER SUPPLY
SHALL BE SIZED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL
CODES.
1. The water line should be a 1/4" (6.35 mm) copper or flexible water line to prevent strain. Do not use low tempera-
ture plastic tubing. The connector on the fill valve is a 1/4" (6.35 mm) male flare fitting.
2. Water line pressure must be from 30 to 70 psi.
3. Install a shut-off valve near the brewer.
4. Install a backflow prevention device that conforms to ASSE Standard #1024.
IMPORTANT
THIS EQUIPMENT IS TO BE INSTALLED WITH ADEQUATE BACKFLOW PROTECTION TO COMPLY WITH
APPLICABLE FEDERAL, STATE AND LOCAL CODES.
5. Installing a filtering system can improve the taste of brewed tea and extend the life of the brewer. The use of a
filter is especially important if your water has a high calcium (lime), chlorine, or iron content. Contact our
Technical Service department to select the filter for your water conditions.
Electrical Requirements
IMPORTANT
THE PERSON INSTALLING THIS APPLIANCE IS RESPONSIBLE FOR ENSURING THAT ELECTRICAL
CONNECTIONS MEET THE REQUIREMENTS OF THE NATIONAL ELECTRIC CODE, STATE AND ANY
LOCAL CODES.
1. The electric ratings for your brewer are printed on its nameplate. The electrical rating is one of the following:
• 120 Volt, 15 Amp, 1 Phase
• 120/208-240 Volt, 20 Amp, 1 Phase, 4 supply wires
2. The brewer should be connected to its own circuit with a fused disconnect switch or a circuit breaker near the
brewer.
American Metal Ware
®
Tea Brewers Page 3
!
WARNING: ELECTRIC SHOCK HAZARD
ONLY QUALIFIED SERVICE PERSONNEL SHOULD PERFORM INSTALLATION OF THIS
APPLIANCE. IMPROPER INSTALLATION COULD RESULT IN ELECTROCUTION.