Haier KGG5202-A1 Range User Manual


 
INSTALLATION
Adapting the cooker to
another type of gas
This operation may only be carried out by
an appropriately authorised fitter.
The cooker is supplied with natural gas
(G20/20mbar).If the cooker is to be supplied
with differs from the gas provided
for the
cooker by the manufacturer, burner nozzles
must be exchanged and the flame needs to
be adjusted.
The cookers provided by the manufacturer
have burners which are factory-adapted to
use the gas specif
ied on their data plates
and guarantee cards.
In order to adapt the cooker to burn a
different type of gas, you should:
Exchange nozzles (see tables below),
Adjust the “economical” flame.
If you need to replace the
natural gas
Burner
Burner flame
Re-arming from liquid
gas
to natural gas
Re-arming from natural
gas
to liquid gas
Full
1. Exchange a burner nozzle for the
appropriate type according to the
nozzle table
1. Exchange a burner nozzle for the
appropriate type according to the
nozzle table.
Economical
2. Unscrew an adjusting bolt slightly
and adjust the flame size.
2. Screw in an adjusting bolt slightly
to the end and check the flame size.
In order to perform adjusting operations, take off the knobs. Adjusting elements of the oven
burner are accessible after drawing out the oven chamber floor.
Surface burners applied do not require adjustment of primary air. A correct flame has
distinct internal cones of blue and green colour. A short, humming flame or long, yellow
and smoking one, without clearly outlined cones, shows improper quality of gas in the
household piping or a damaged or soiled burner. In order to check a flame, heat a burner
for around 10 minutes with a full flame, and next turn the valve knob to the economical
flame position. The flame should not go out or jump onto the nozzles.
GB
Caution!
Nozzle(mm) type/diameter
Type of gas
auxiliary
medium
large
oven
a
NG /20 mbar
0.76
0.99
1.17
0
LPG /30 mbar
0.55
0.71
0.9
0.76
0.68
1.06
1.06
1.3
0.9
0.9
1.3
1
KGG5201
KGG5202
KGG6201
KGG6202
-A1
-A1
-A1
-A1
x
34
(G20/20mbar) nozzle, please contact
the service center.
INSTALLATION
Exchange of a burner
nozzle unscrew the
nozzle with special socket
spanner No 7 and replace
with a new one according
to a type of gas (see
tables)
Adapting the appliance to a different
type of gas than that indicated by the
manufacturer of the cook
er on the
data plate, or purchasing a cooker for
a different type of gas than supplied to
the house,
is exclusively the
responsibility of the user and the
fitter.
After adjustment is completed, place a
label indicating the type of gas to
which the cooker is now ad
apted.
In cookers with a safety device, a knob
with a surface burner safety valve is used,
fig.B. Knobs should be adjusted with the
burner switched on and set to the
economical flame position, using an
adjustment screwdriver of the 2.5mm size.
Fig. B
A knob with a
surface burner
safety valve
Fig.C
Adjust the air flow of the oven burner
a
GB
Caution!
35
Electrical connections
Electric connection may be carried
out by qualified service personnel
only!
Wrong connection may permanently
damage parts of the appliance and
render your warranty void!
Mains voltage of the user(120V)must
be verified with the measuring device!
Three separrating switches should be
placed in accordance with the mains
connection.
Mains lead behind the cooker must be
placed in such manner to avoid
touching the back panel of the cooker
because of the heat it develops during
operation.
The mains lead extension may be
made by qualified personnel only.
Repairs of electrical parts may be
carried out only by qualified
electrician.In case of malfunction call
the service center.
Connection
Using the screwdriver open the
connector cover at the rear of the
appliance.Release two locks located
at either side of the connector bottom.
Mains lead must be led through the
relief safety device,protecting the
mains leadcable from disconnection.
Tighten the relief device securely and
close the connector cover.