This is an electro-mechanical device that causes pressure to be
held in the frypot. The solenoid valve closes at the beginning
of the Cook Cycle and opens automatically at the end of the
Cook Cycle. If this valve should become dirty, or the Te on
seat nicked, pressure will not build up. The electric fryer uses a
208/240 volt 60 hertz coil (50 hertz internationally).
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
Coil Check Procedure
Remove the solenoid wires from the wire nuts which are found
behind the control panel. Check across wires.
RESULTS
208/240 Volt, 60 Hertz 150 Ohms
208/240 Volt, 50 Hertz 230 Ohms
Replacement
1. Remove the right side panel.
2. Remove the “tru-arc” retaining clip on top of coil housing.
3. Remove the cover.
4. If only the coil is to be replaced, disconnect two coil wires
at wire nuts in the coil housing. Remove coil, insert new
coil, and connect wires at wire nuts. Assemble in reverse
order of disassembly.
The wires may be connected in any order.
2-12 1103
2-15. SOLENOID VALVE