Henny Penny 590 Fryer User Manual


 
Model 590/592
To avoid electrical shock of property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
Replacement
1. If the tube is broken or cracked, the control will open,
shutting off electrical power. The control cannot be reset.
2. Drain shortening from the frypot and discard. A substance
in the tube could contaminate the shortening.
3. Remove control panel.
4. Loosen small inside screw nut on capillary tube.
5. Remove capillary bulb from bulb holder inside the frypot.
6. Straighten the capillary tube.
7. Remove larger outside nut that threads into pot wall, and
remove defective control from control panel area.
8. Insert new control and replace screws.
9. Uncoil capillary line, starting at capillary tube, and insert
through frypot wall.
To avoid electrical shock or other injury, run capillary
line under and away from all electrical power wires and
terminals. The tube must never be in such a position
where it could accidentally touch the electrical power
terminals.
10. Carefully bend the capillary tube as shown in photo and
place into bulb brackets.
1103 2-3
2-4. HIGH TEMPERATURE
LIMIT CONTROL
(Continued)