Henny Penny 590 Fryer User Manual


 
Model 590/592
11. Pull excess capillary line from pot and tighten nut into
frypot wall.
Be sure capillary bulb of high limit is positioned so it does
not interfere with carrier or get damaged when cleaning
frypot.
12. With excess capillary line pulled out, tighten smaller nut.
13. Replace inner and front panels.
14. Re ll with shortening.
There are two fuse holders on each model of the electric fryers.
To check or change fuse, unscrew black fuse holder cap.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
Checking Procedure for Fuse Holders
CONTROL PANEL FUSES 3 Phase
Remove the control panel and pull the wires from the fuse
holder terminals. Using a multimeter or continuity light, check
across the terminals. The circuit should be closed. If not, re-
place the fuse (HP# EF02-007) or fuse holder (HP# EF02-006).
2-4 1103
2-4. HIGH TEMPERATURE
LIMIT CONTROL
(Continued)
2-5. FUSE HOLDERS