4.3.1 Three-phase power connection
The unit is delivered without a power cable and with a three-phase terminal
connection.
1. Prepare the connection cable (cable type H07RN-F compliant with
EN-Norm).
2. Remove the back panel.
3. Pass the connection cable through the strain relief screws into the
unit.
4. Tighten the strain-relief screws securely so that the power cable
cannot be pulled out.
5. Connect the power cable to the terminals.
6. Remount the back panel.
4.3.2 Single-phase power connection (only SpaceSaver)
The unit is delivered without a power cable and with a three-phase terminal
connection.
NOTICE
Size 605 units in the 380 V, 400 V and 415 V versions can also be
single-phase connected.
The unit's connected output is reduced with a single-phase connection
(see Chapter “Specifications, power supply”, Page 13).