Hobart AM14T Dishwasher User Manual


 
12
OPTIONAL EQUIPMENT CONNECTIONS Vent Fan and Gas Booster
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE
PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT
SWITCH TO INDICATE THAT YOU ARE WORKING ON THE CIRCUIT.
Vent Fan Control
The vent fan control feature is standard on machines with gas heat; it is a field installable accessory
on machines with electric heat.
The maximum switching rating for a vent fan control relay connected to terminals VFC1 and FVC2 is
1.5 Amps. The vent fan control relay provides switch contacts only and does not provide the power
supply for the vent fan motor. When the dishwasher is connected to the vent fan, the vent fan relay
is switched on when the dishwasher is on, and off when the dishwasher is off.
Hobart Infrared Booster Gas Water Heater
The maximum rating for connecting a Hobart Model IB57 Dishwasher Activated infrared gas booster
water heater to BSTR1 and BSTR2 is 0.5 Amp at 24 Volts. If a Stand Alone Booster Heater is used,
no electrical connection to the dishwasher is allowed. Refer to the Infrared Booster Gas Water Heater
Manual for additional installation details.
ELECTRICAL DATA
Model Volts / Hz / Ph Tank Heat
Minimum Circuit Ampacity
Maximum Protective Device
AMPS
Dishwasher ONLY
Optional 13 KW
Electric Booster ONLY
AM14T
AM14TC
AM14F
208 - 240 / 60 / 1
Electric 60
Gas 20
208 / 60 / 1 Electric 80
240 / 60 / 1 Electric
80
208 - 240 / 60 / 3
Electric 30
Gas 15
208 / 60 / 3 Electric 50
240 / 60 / 3 Electric
50
480 / 60 / 3
Electric 15 25
Gas 15
Compiled in accordance with the National Electrical Code, ANSI / NFPA 70 (latest edition).